客戶至上
電話:15378180513
聯(lián)系人:
官網(wǎng):http://byzgrb.cn
客戶用一臺S5500-28C-EI做環(huán)路檢測,全局和接口下配置了環(huán)路檢測,環(huán)路檢測執(zhí)行動作為shudown,使用一根網(wǎng)線將設(shè)備的G1/0/7和G1/0/8互聯(lián),結(jié)果G1/0/7和G1/0/8沒有被執(zhí)行shudown,而其他接口被shudown了,客戶對此操作結(jié)果表示疑問。
正常情況下,將設(shè)備的G1/0/7和G1/0/8互聯(lián),配置環(huán)路檢測執(zhí)行shudown操作,應該是G1/0/7和G1/0/8被shudown,其他接口不受影響,那么為什么會產(chǎn)生客戶現(xiàn)場的情況呢?
1、首先檢查配置:
interface GigabitEthernet1/0/7
port link-mode bridge
port access vlan 8
loopback-detection enable
loopback-detection action shutdown
#
interface GigabitEthernet1/0/8
port link-mode bridge
loopback-detection enable
loopback-detection action shutdown
其他接口下未進行相關(guān)配置,檢查配置未發(fā)現(xiàn)問題。
2、設(shè)備日志確認:
GigabitEthernet1/0/7 link status is UP.
GigabitEthernet1/0/8 link status is UP. //G1/0/7和G1/0/8用網(wǎng)線互聯(lián)后up
%Mar 20 12:54:47:588 2020 ww_jiao-LLDP/6/LLDP_CREATE_NEIGHBOR: New neighbor created on Port GigabitEthernet1/0/8 (IfIndex 9437191), Chassis ID is 70f9-6d80-5acf, Port ID is GigabitEthernet1/0/7.
%Mar 20 12:54:47:919 2020 ww_jiaowei-LLDP/6/LLDP_CREATE_NEIGHBOR: New neighbor created on Port GigabitEthernet1/0/7 (IfIndex 9437190), Chassis ID is 70f9-6d80-5acf, Port ID is GigabitEthernet1/0/8.
%Mar 20 12:55:08:281 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: Ten-GigabitEthernet1/1/2 link status is DOWN.
%Mar 20 12:55:08:423 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/28 link status is DOWN.
%Mar 20 12:55:08:616 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/27 link status is DOWN.
%Mar 20 12:55:08:809 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/26 link status is DOWN.
%Mar 20 12:55:09:004 2020 ww_jiaowei_30F_huiju IFNET/3/LINK_UPDOWN: Ten-GigabitEthernet1/1/1 link status is DOWN. //G1/0/7和G1/0/8用網(wǎng)線互聯(lián)后其他接口被shudown。
G1/0/7和G1/0/8down后,被down接口重新up。
15:240 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/8 link status is DOWN.
%Mar 20 12:55:15:372 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/7 link status is DOWN. //G1/0/7和G1/0/8接口down。
%Mar 20 12:55:38:901 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: Ten-GigabitEthernet1/1/2 link status is UP.
%Mar 20 12:55:39:058 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/27 link status is UP.
%Mar 20 12:55:39:233 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/28 link status is UP.
%Mar 20 12:55:39:378 2020 ww_jiaowei_IFNET/3/LINK_UPDOWN: Ten-GigabitEthernet1/1/1 link status is UP. //被down接口up。
3、在設(shè)備上查看環(huán)路檢測狀態(tài),顯示未生效。
dis loopback-detection
Loopback-detection is running.
Detection interval is 30 seconds.
No port is detected with loopback. //環(huán)路檢測未生效
4、查看版本說明書并無相關(guān)已知問題,后續(xù)和產(chǎn)品線確認后了解到缺省情況下,多端口環(huán)路檢測模式處于關(guān)閉狀態(tài),需要手動配置loopback-detection multi-port-mode enable開啟多端口環(huán)回監(jiān)測模式,現(xiàn)場設(shè)備未開啟多端口環(huán)回監(jiān)測,因此導致以上的異常情況產(chǎn)生,配置后解決。
解決方法多端口環(huán)路檢測模式處于關(guān)閉狀態(tài),需要手動配置loopback-detection multi-port-mode enable開啟多端口環(huán)回監(jiān)測功能,實現(xiàn)GigabitEthernet1/0/7與GigabitEthernet1/0/8端口間的環(huán)回監(jiān)測后解決。
開啟多端口環(huán)回監(jiān)測模式后,若系統(tǒng)如果監(jiān)測到端口間存在環(huán)回,會對被環(huán)回的端口進行相應的操作:
對于Access端口,則根據(jù)環(huán)回監(jiān)測動作對該端口進行相應的操作,并向終端上報Trap信息,同時刪除該端口對應的MAC地址轉(zhuǎn)發(fā)表項;
對于Trunk端口或Hybrid端口,則只向終端上報Trap信息。當端口的環(huán)回監(jiān)測受控功能也同時開啟時,系統(tǒng)根據(jù)環(huán)回監(jiān)測動作對該端口進行相應的操作,并向終端上報Trap信息,同時刪除該端口對應的MAC地址轉(zhuǎn)發(fā)表項。
Copyright ? 2024 達銳斯科技 川公網(wǎng)安備 51010802000119號